Skip to main content

LP-21700 User Manual

Daily Use​

Charging​

  1. Use a dedicated LiFePO4 charger
  2. Charging temperature: 0°C ~ 45°C
  3. Charge current should not exceed 1C
  4. Disconnect charger after full charge

Discharging​

  1. Discharge current should not exceed 2C
  2. Discharge temperature: -20°C ~ 60°C
  3. Avoid deep discharge (DOD > 80%)

Maintenance​

Regular Inspection​

  • Check voltage monthly
  • Check appearance monthly
  • Check connections quarterly

Cleaning​

  • Wipe with dry cloth
  • Do not use chemical cleaners

Troubleshooting​

IssuePossible CauseSolution
Overheating during chargeCharge current too highReduce charge current
Fast voltage dropCapacity degradationReplace battery
Cannot chargeBMS faultCheck protection circuit

Disposal​

Please recycle batteries according to local regulations. Do not dispose of in regular trash.